Stress and resting ECG with suction system
custo cardio 400 is our resting and stress ECG with suction system in one device. It sets new standards in functionality, operability and hygiene. After intensive testing, custo cardio 400 has been awarded with the certificate of the German Society for Hospital Hygiene (just like custo cardio 200). By means of exchangeable, reusable suction electrodes a totally hygienic and sustainable application is guaranteed.
Accessories
Frequency response: 0 to 0.262 * sampling frequency [HZ]
Sampling frequency: 1000, 2000, 4000, 8000, 16000 (only USB), 32000 (only USB) Hz
Sampling rate: Identical for all channels, possible settings: 1.0 ms / 0.5 ms / 0.25 ms / 0.125 ms / 0.0625 ms (only with USB) / 0.03125 ms (only with USB)
Deviation: < 1.5 %
A/D converter: 24 bit
Input impedance: > 50 MΩ
Amplitude quantification: 1.526 μV/bit
CMRR: > 93 dB
Defibrillation protection: Electrical strength 5000 V (recovery time < 5 s)
Suction power: 6 levels, 0 – 280 mbar (in 40 mbar increments)
Power supply: 12 V power supply unit
Max. power consumption: 7 Watt
EDP connection: USB (3 m) and Bluetooth 2.1 EDR
Bluetooth range: Generally 10 m, depending on ambient conditions
Dimensions: 250 x 110 x 60 mm (L *x W x H)
Weight: Approx. 680 g (device without leads and electrodes)
Patient leads: Approx. 1450 mm (extremities), approx. 1200 mm (precordial)
Classification: Device with external power supply, Class IIa according to MDD, Type CF application part
Underlying standards: IEC 60601-1, DIN IEC 60601-2-25, IEC 60601-1-2
Reusable electrodes
Service is essential to keep medical equipment operational and safe. Our Nordic service team consists of experienced service technicians stationed across the Nordic countries. Our service technicians are ready to take on your every service need.”

Delivering Confidence and Simplicity during Neuromuscular Blockade
TetraGraph is a quantitative neuromuscular transmission monitor based on electromyography (EMG). The TetraGraph monitor stimulates, measures, analyzes and displays muscle function in surgical patients receiving neuromuscular blocking agents (NMBAs). NMBAs are used in almost 50% of surgical cases. Inadequate reversal of NMBAs can lead to residual neuromuscular blockade (RNMB). RNMB delays recovery and can lead to life-threatening complications. To prevent complications, quantitative neuromuscular monitoring is rapidly becoming the standard of care when NMBAs are administered.

Helping heal one step at a time
From rehabilitation to orthopedics to physical therapy, the PPS (Professional Power System) Med treadmill provides comfort and assistance to patients who require walking support. This treadmill can accommodate any user’s pace with an absolute zero start speed with increments of 0.1 mph.

For all essential spirometry testing
The modular JAEGER Vyntus™ PNEUMO belongs to the Vyntus Family and is combinable with Vyntus APS for bronchial challenge testing and/or Vyntus IOS Impulse Oscillometry for measuring central and peripheral airway resistance.
Use your Vyntus Pneumo for all of the essential spirometry testing: Flow/Volume-loop (FVC), Slow Vital Capacity (SVC), Maximum Voluntary Ventilation (MVV), Pre and Post medication testing or therapy control.
Optionally, Vyntus Pneumo allows expanding your diagnostic possibilities with measurements like Rocc, P0.1, Pmax, SNIP, rhinomanometry and compliance. Vyntus Pneumo is enhanced by the workflow- and quality-driven SentrySuite™ Software.
The reliable, proven, accurate, heated Jaeger pneumotach has been selected as the measurement device of choice in hundreds of publications. Its excellent dynamic range allows for testing a broad population, from small children to athletes. Thousands of PFT labs profit daily from its high performance.

The dual-valved LiteAire MDI holding chamber: Collapsible, disposable paperboard design.
The LiteAire® collapsible MDI holding chamber is a unique MDI holding chamber and an innovative alternative. LiteAire’s unique dual-valved MDI holding chamber design delivers pop-up convenience and effective drug output at a fraction of the cost of most plastic holding chambers. In many clinical settings, the LiteAire can reduce costs by replacing existing rigid plastic holding chambers or inefficient spacers with a paperboard alternative. The unique design allows the LiteAire to be reused by a patient over multiple doses and meets and often exceeds the performance of plastic holding chambers.