The RAPIDPoint 500e System elevates Siemens Healthineers blood gas offering to a new level, allowing you to spend more time focused on patient care. Implement a proven end-to-end blood gas solution that reduces the daily burden of device management and enables you to give your full care and attention where it matters most.
With an improved user experience, the analyzer transforms care delivery, setting an elevated standard in simplicity, quality assurance, and data security for healthcare organizations
|
Parameters |
Analyte |
|
Blood Gas |
pH, pCO2 and pO2 |
|
Electrolytes |
Na+, K+, Ca++ and CI– |
|
Metabolites |
Glucose and Lactate |
|
CO-oximetry |
tHb, sO2, O2Hb, HHb, COHb, MetHb and Neonatal Total Bilirubin |
The RAPIDPoint 500e system also supports additional sample types: pleural fluid pH; Na+, K+, Ca++, Cl–, pH, pCO2, and HCO–3(act)† for dialysate fluid‡ samples.
†pH, pCO2, and HCO–3(act) are provided for reference only.
|
Sample volume |
100 µL |
|
Analysis |
Time to results is approximately 60 seconds |
|
Quality Control |
Automatic QC or ampule QC
Three levels of independent quality control solutions Customizable QC schedule |
|
Measurement Cartridge |
Cartridge initialization time is approximately 24 minutes |
|
Use life |
28 days onboard, or maximum number of tests
|
|
Integrated Barcode Scanner |
1D barcode symbologies – Code 128, Codabar, Code 39, Character/Digit, Interleaved 2 of 5 2D barcode symbologies – PDF417, MicroPDF417, Datamatrix, QR Code, Micro QR Code, Aztec, and Maxicode |
|
Operating System |
MICROSOFT WINDOWS 10 IoT
|
| Communications | LIS Wireless Dual-port transmission via Ethernet and serial port POCcelerator™ Data Management System POCcelerator SE Data Management System |
Healthcare professionals are increasingly under pressure to deliver quality care in busy critical care settings. Any delay, distraction, or concern in the generation and reporting of test results physicians rely on can add to the operational burden and take time and focus away from the patient.
To give you confidence in every result while reducing the time to diagnosis and treatment, the RAPIDPoint 500e system provides robust accuracy from sample to sample by leveraging the Siemens Healthineers-designed Integri-sense™ Technology—the guardian of patient results. Integri-sense Technology is a comprehensive series of analyzer functional checks and flagging mechanisms designed to deliver accurate test results. It performs frequent quality and blood integrity checks before, during, and after every patient sample. Three levels of independent automatic quality control, multiple calibration routines, and advanced software algorithms combine to enable the RAPIDPoint 500e analyzer to be ready to generate reliable and clinically actionable test results each and every time.
Depend on the RAPIDPoint 500e system to raise the bar in blood gas IT security at your facility with the latest defenses to guard confidential patient data coupled with the leading built-in technology to protect your institution from external cybersecurity threats. The WINDOWS 10 operating system has been equipped with McAfee embedded anti-malware, which blocks unknown and unauthorized programs from running. Other key security advantages include a two-step authentication process, an encrypted password requirement for patient data transfer, and the inclusion of a firewall to block hacking attempts.
This user-friendly and maintenance-free analyzer provides the patient results most needed by clinicians in critical care environments. The simplicity of the RAPIDPoint 500e system centers on the fact that it is a fully cartridge-based analyzer, with no maintenance required. The measurement cartridge includes the planar sensors, sample probe, and CO-ox chamber, so all these components are replaced with every new cartridge.
One of the unique features of the RAPIDPoint 500e system is the sample port. Syringe and capillary samples are handled in exactly the same way, and operator variability is eliminated with hands-free automatic sampling. Only 100 µL of sample is aspirated, and the sample port is part of the advanced clot management and air bubble detection mechanism.
Integri-sense Technology is the guardian of patient results. The system performs frequent quality and sample integrity checks before, during, and after every patient sample. Automatic quality control, comprehensive calibrations, and advanced software algorithms combine to enable the analyzer to be ready to generate reliable, clinically actionable results each and every time, delivering confidence with every result.
Service is essential to keep medical equipment operational and safe. Our Nordic service team consists of experienced service technicians stationed across the Nordic countries. Our service technicians are ready to take on your every service need.”

Vyntus™ SPIRO PC Spirometer
The Vyntus™ SPIRO was born out of Vyaire’s obsession to perfect a spirometer that is easy-to-use and has the flexibility to provide accurate results for both the general user and sophisticated lab. Stationary or portable PC spirometer as a stand-alone device or as part of the SentrySuite network.
Thousands of PFT labs depend every day on Vyaire’s proven, accurate and reliable JAEGERTMpneumotach. For hundreds of publications, the JAEGER pneumotach was the device of choice.
Its excellent dynamic range effectively tests a broad population from small children to athletes.

IOS Impulse Oscillometry
Tidal breathing analysis with Impulse Oscillometry (IOS) has demonstrated to be informative and differentiated in the early detection and follow up of pulmonary diseases like asthma, COPD and idiopathic pulmonary fibrosis. IOS is almost independent of patient cooperation and can test a larger patient range than spirometry alone, from children to adult to geriatric patients.
IOS is available as a stand-alone device combined with a spirometry measurement program (MasterScreen IOS and Vyntus IOS) or as an add-on module to the MasterScreen series.

For all essential spirometry testing
The modular JAEGER Vyntus™ PNEUMO belongs to the Vyntus Family and is combinable with Vyntus APS for bronchial challenge testing and/or Vyntus IOS Impulse Oscillometry for measuring central and peripheral airway resistance.
Use your Vyntus Pneumo for all of the essential spirometry testing: Flow/Volume-loop (FVC), Slow Vital Capacity (SVC), Maximum Voluntary Ventilation (MVV), Pre and Post medication testing or therapy control.
Optionally, Vyntus Pneumo allows expanding your diagnostic possibilities with measurements like Rocc, P0.1, Pmax, SNIP, rhinomanometry and compliance. Vyntus Pneumo is enhanced by the workflow- and quality-driven SentrySuite™ Software.
The reliable, proven, accurate, heated Jaeger pneumotach has been selected as the measurement device of choice in hundreds of publications. Its excellent dynamic range allows for testing a broad population, from small children to athletes. Thousands of PFT labs profit daily from its high performance.

The Katana sport is a modern and reliable treadmill that can be connected to external ECG- and pulmonary devices as well as to a Lode software network (LEM or LCRM). The Lode Katana sport offers smooth acceleration and is continuously adjustable in a range of 0,5 – 30 km/h. The walking surface of 190 x 70 cm and elevation of 0 – 25%, make this treadmill the perfect solution for use in sport medical settings. The treadmill is equipped with a 7″ Control Unit with Touchscreen and fixed side handrails. The treadmill is executed with a special Lode Slat Technology with 106 soft grip covered slats that allows for high speed and a natural walking and running treadmill experience. Its Unique bearing technology delivers high speeds at low noise levels while needing low maintenance.