Untethered six-minute walk test
Vyntus™ WALK allows patients to perform an untethered six-minute walk test (6MWT) by wearing wireless sensors that communicate data to a technician-held tablet PC. Standardize testing to the recommended is 6MWT protocol, because consistent testing yields consistent data for comparison
The system is both patient- and technician-friendly and because we know a single sensor does not fit all clinical needs, comes with an array of easy-to-wear sensors. Because standardizing the complete testing process is critical to meaningful data for patient trending, Vyaire has integrated the complete ATS testing standards in the workflow-driven tablet software application.
It is likely that multiple technicians will be asked to perform 6MWTs on patients. Without a strict, standardized protocol, each technician could slightly vary how they run the test, what commands they give the patient, and the parameters they record, all of which can lead to variable data that delivers less-accurate data trends. Vyntus WALK is standardized to run the recommended American Thoracic Society (ATS) 6MWT protocol, because accurate comparison requires consistent testing that yields consistent data.
One of the cardinal rules of a good 6MWT is to have the patient walk of their own volition. But if the patient is tethered to the technician by a pulse oximeter cable, and the technician is walking just behind the patient, the patient’s performance can be directly influenced or affected. Vyntus WALK uses Bluetooth™ wireless pulse oximeter technology that allows the patient to move through the entire course and limits technician influence. Also, the sensor provides a more complete HR and SpO2 reading over time.
Not every clinician prefers to view data the same way. That’s why with Vyntus WALK, you first see the data as its being collected graphically over time. But with the simple swipe of a finger, you can switch to the Easy-View mode, displaying large numeric values for HR and SpO2. Swipe back, and you are back to viewing graphically over time. And if the patient needs to pause, Vyntus WALK will continue to show both active HR and SpO2 values throughout the pause time screen.
Vyntus WALK can be run as a standalone device generating a standard report, or the data can move in and out of SentrySuite software for a more robust interpretation and trending report
As a standalone device, users quickly enter patient demographics directly on the tablet PC, run the 6MWT, and print a standard report using one of two options:
As a device connected to SentrySuite, users receive demographics from SentrySuite, run the 6MWT, and then return completed test data to SentrySuite. From SentrySuite, more options are available:
Service is essential to keep medical equipment operational and safe. Our Nordic service team consists of experienced service technicians stationed across the Nordic countries. Our service technicians are ready to take on your every service need.”

Versatile Airway Clearance
Introducing the Clearway 2 with TreatRepeat®. The second-generation MI-E device by Breas incorporates the latest technology to bring effective and accurate treatment for patients requiring airway clearance and cough assistance. TreatRepeat function allows clinicians to manually deliver different numbers of insufflations and exsufflations and then save the treatment they have just delivered to the device to be repeated automatically. Helping to improve accuracy and speed of titration and set-up.
Multiple mode options
Up to four treatment profiles can be saved to the device.The settings used in the manual and programmed modes are also saved to the device. This allows for up to 7 MI-E prescriptions to be saved. The treatment settings in the IPPB and NIV modes are also saved. The programmable mode enables the delivery of multiple insufflations as part of a cough cycle.

Vyntus™ BODY Plethysmograph
People come in all shapes and sizes, so we designed Vyntus BODY to accommodate the most patients without increasing the cabin footprint. Many enhancements were incorporated to make Vyntus BODY accessible and user friendly for both patients and technicians.
Vyntus BODY employs much of the same breakthrough technology found in the Vyntus ONE, but with a redesigned breathing circuit and our new Ultrasonic Sensor Technology.
In addition, Vyntus BODY is enhanced with additional innovation such as digital pressure compensation, which helps to reduce environmental influences and improves measurement accuracy.

A step up in professional exercise diagnostics
The Vyntus™ CPX is an accurate, reliable system that collects full breath-by-breath data and allows the determination of a subject’s metabolic response. It can be used on adults and children, whether patients or athletes.
The Vyntus™ CPX is the result of over 50 years of experience in the development of CPET devices. Together with the Vyntus™ ECG, this Metabolic Cart is a powerful combination.

Pulmonary Function Testing from infant to adult patients
The EXHALYZER® D offers various lung function tests for infants (>3 kg), children and adult patients. The modular system is easily upgradable and fully compliant with the ATS / ERS recommendations for infant and pediatric pulmonary function testing.